    1M3 VOC emissions test chamber for automotive interior, automotive indoor emission test chambers

    Ask Lasest Price
    Brand Name : Simplewell
    Model Number : V-series
    Certification : CE
    Price : 60000~120000
    Supply Ability : 10 sets per month
    Delivery Time : 50 working days
    • Product Details
    • Company Profile

    1M3 VOC emissions test chamber for automotive interior, automotive indoor emission test chambers

    1M3 VOC emissions test chamber for automotive interior



    1M3 VOC emissions test chamber for automotive interior, automotive indoor emission test chambers


    Volatile organic compounds (VOCs) can have an adverse reaction on technical products, components, humans, and the environment. With society development, people's life standard improvement, people more care about health, customer care about the harmful substance inside of vehicle. And also the Nation care about environmental protection and care about people health (GB/T 27630-2011 and HJ/T400-2007 Focus on 8 substances with limits for a car interior measured at RT; Law GB 27630 draft 2017 might come end of 2017; China Laws and regulations). By our available VOC emission chamber for automotive interior + GC/MS, test your the automotive interiors under the right conditions to ensure the safety and integrity of pieces, parts and products.


    Advantages of Simplewell automotive interior VOC emission chamber


    The method reduces the adsorption capacity of the contact surface, greatly reduces the adsorption of a test object on the inner wall of the chamber and on the surface in contact with the test object of each component, so that the tested value of the samples taken from a sampling tube is closer to the actual value of the test object in the chamber, effectively improving the testing precision of the releasing chamber. EUROPEAN, USA, JAPAN PATENT OF (METHOD FOR TREATING SURFACE OF RELEASING CHAMBER IN CONTACT WITH TEST OBJECT).


    The coated stainless steel wall improves the adsorption capacity of test chamber of high-boiling-point materials and polar compounds. The chamber emission gas recovery rate more than 80% of tetradecane and 4-phenyl-1-cyclohexene. It increased testing accuracy.

    1M3 VOC emissions test chamber for automotive interior, automotive indoor emission test chambers

    Patent of METHOD FOR TREATING SURFACE OF RELEASING CHAMBER IN CONTACT WITH TEST OBJECT


    Technical parameter of 1M3 automotive interior VOC emission chamber


    Product ModelEV-1000AEV-1000B
    Volume chamber (W×D×H) mm1580×800×800900×1000×1100
    Environmental temperature5~ 35ºC
    Environmental humidity≤ 90% R.H
    Requirements for EnvironmentalNo pollutant source in surrounding environment
    Adjustable range of temperature20~ 100ºC high temperature cleaning 250ºC
    Adjustable range of humidity30~80%R.H.(20~30 ºC) Match ADA276 5% when catch 65ºC
    Pressure10±5pa
    Temperature fluctuation±0.3ºC (Fluctuation)
    Temperature deviation±0.5 ºC (Deviation)
    Humidity fluctuation±2.5%R.H
    Humidity deviation±3% (Deviation)
    Air exchange rate0.2~5/h±5% (Larger exchange rate optional)
    PowerAlternating current 380V/50HZ three-phase power supply 4/5 wiring system
    Rate of recoveryFormaldehyde, octanol, 4 phenyl Cyclohexene, dodecane and tetradecane have a recovery rate>80%
    Purifier systemStandard configuration
    Background concentration of VOCSingle VOC has a concentration smaller than 2µg/m³, T VOC 20µg m dust filtrated TVOC has a concentration <20µg/m³

    Cases (only part of vehicle interior components testing customer list)


    No.CustomerProduct name and modelQTY
    1Changchun faway Johnson Controls Automotive Trim Systems Co. Ltd(May. 2014)1M3 VOC testing chamber V-1000-2761set
    2Zhejiang Geely Automobile Co-Hangzhou (Jan. 2016)1M3 VOC testing chamber V-1000-2761set
    3Huntsman Chemical Trading (Shanghai) Co., LTD
    (2012) (May. 2015)
    1M3 VOC testing chamber V-1000-2762sets
    4BHMC
    Beijing Hyundai Motors (Mar. 2013)
    1M3 VOC testing chamber V-1000-2761set
    5Ningbo automotive parts inspection center (Apr.2014)1M3 VOC testing chamber V-1000-2761set
    6Guangzhou quality supervision and testing Institute (May. 2017)1M3 VOC testing chamber V-1000-2761set
    7SCISKY company(Apr. 2017)1M3 VOC testing chamber V-1000-2761set
    8Harbin Xinda macromolecule material Co., LTD (Jan. 2014)1M3 VOC testing chamber V-1000-2762sets
    9Jiangsu entry-exit and quarantine bureau industrial testing center (Jan. 2014)1M3 VOC testing chamber V-1000-2761set
    10Wuhu product quality supervision and Inspection Institute (Sept. 2014)1M3 VOC testing chamber V-1000-2761set
    11Chongqing measuring quality inspection Inst (Jul. 2014)1M3 VOC testing chamber V-1000-2761set

    Implementation Standards


    Standard No.Item
    GB18580-2001Formaldehyde Emission of Manmade Board and Its Products
    GB18584-2001Indoor Decorating and Renovating Materials Limits of Harmful Substances in Wooden Furniture
    GB18587-2001Indoor Decorating and Renovating Materials Releasing limitation of Harmful Substances from Carpet,Carpet Pad and Carpet Adhesive
    ASTM D6007-02Standard Test Methods for Determination of Formaldehyde Concentration in Gases Released from Wood Products with Small Scale Environmental Chamber
    ENV717-1Environmental Chamber Method for Measurement of Formaldehyde Emission of Manmade Board
    EN13419-1Determination of VOCs Release quantity of Building products Chapter One The Method for Releasing and Testing the Environmental Chamber
    HJ 571-2010Technical Requirements for Environmental Labeling Manmade Board and Its Products
    HJ 566-2010Technical Requirements for Environmental Labeling Manmade Board and Its Products
    VDA 270Odour
    VDA 275Formaldehyde
    VDA 276VOC, SVOC Test Chamber
    VDA 277VOC Headspace
    VDA 278VOC, SVOC Direct desorption
    ISO12219 series

    Reference Standards

    Standard No.Item
    ASTM D5116-97Standard Guide for Determination of Organic Release from Interior Materials and Products with Small Scale Environmental Chamber
    ASTM D6330-98Standard Operation for Determination of VOCs (Excluding Formaldehyde) Release from Wooden Board with Small Environmental Chamber under Specified Test Conditions
    ASTM D6670-01Standard Operation for Determination of VOCs Release from Interior Materials and Products with Full Scale Environmental Chamber
    ASTM E1333-96Standard Test Methods for Determination of Formaldehyde Concentration and Release Rate in Gases Released from Wood Products with Large Scale Environmental Chamber

    For futher information pls contact with us:

    ItemDetail Information
    Phone&Wechat&Whatsapp ID0086 186 7605 0580
    EmailSimplewell02@163.com;sales01@simplewell.com.cn
    Skype0086 186 7605 0580
    QQ

    1181717893


    Quality 1M3 VOC emissions test chamber for automotive interior, automotive indoor emission test chambers for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Simplewell technology Co., LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)